Storage and SAN Performance   Leave a comment

VMAX Thin Provisioned Frame Performance analyze

A.The key performance indicator is IO Density and they should looks at it 2 ways.

B. Relative numbers. If EFD is > than FC and > SATA, then data placement and FASTVP is being effective.

C. And then look at the IO Density per tier.  When EFD or FC gets too high, they need to add spindles.  If SATA is too high and there is space left in FC and EFD, then they probably have some policy adjustments needed or something else going on.

D. The absolute planning or threshold number will vary by drive size, speed, etc.

Format for Reporting

` Location Pool Name Total Capacity in TB Allocated % Allocated TB Subscribed % Subscription in GB

1234-VMAX

Site X

EFD

20.0625

21

4.213125

0

FC_VP_Pool1

200.6633301

4

8.026533203

58

116.3847314

SATA_VP_Pool1

383.5470703

6

23.01282422

0

Total Physical Capacity Usage on the Frame

35.25248242

Total Usable Capacity Available on Frame

604.2729004

Storage Subscription(Provisioned) to the host

116.3847314

Thick Subscription  Remaining on the Frame(if Less than 50TB Value is Red)

487.8881689

IF this Value is 0 Then we are moving on the Over Subscription on the Frame
Is FC Pool  Usage(Real Data) more than 75% Storage

4

IF this is Red please Buy FC storage else We will see Performance issues with Data on SATA
Array Name Location Pool Name Total Capacity in GB Allocated % Allocated TB Subscribed % Subscription in GB

4321-VMAX

Site Y

EFD

5.015625

86

4.3134375

0

FC_VP_Pool1

34.2578125

61

20.89726563

389

133.2628906

SATA_VP_Pool1

119.859375

11

13.18453125

0

Total Physical Capacity Usage on the Frame

38.39523438

Total Usable Capacity Available on Frame

159.1328125

Storage Subscription(Provisioned) to the host

133.2628906

Thick Subscription  Remaining on the Frame(if Less than 50TB Value is Red)

25.86992188

IF this Value is 0 Then we are moving on the Over Subscription on the Frame
Is FC Pool  Usage(Real Data) more than 75% Storage

61

IF this is Red please Buy FC storage else We will see Performance issues with Data on SATA

Posted January 11, 2013 by g6237118

Leave a comment